JS Consulting Group, LLC.

12180 Ridgecrest Road Ste. 314
Victorville, CA 92395
760) 843-4098 f. 760) 241-7076

Client
Joe Buyer

Home
123 Sweet Road.
Home town, CA

Real Estate Agent
Shear Realty SVL

Inspection Date 
Thursday, December 18, 2003

Inspected By 
Jim Stasiak

STRUCTURAL SYSTEM

According to ASHI Standards and Practices: The Inspector shall inspect the structural components including foundation and framing which may involve probing a representative number of structural components where deterioration is suspected or where clear indications of possible deterioration exists. Probing is NOT required when probing would damage any finished surface or where no deterioration is visible. The inspector shall describe the foundation and report the methods used to inspect the under-floor crawlspace. Describe floor structure, wall structure, ceiling structure and roof structure and report the method used to inspect the attic.

I=Inspected, NI=Not Inspected, NP=Not Present, R=Not Functioning or in Need of Repair
I NI NP R  Inspection Items
x   1.0 FOUNDATIONS (Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components.)
Comments: 
x   1.1 FLOORS (Structural)
Comments: 
x   1.2 WALLS (Structural)
Comments: 
  x 1.3 COLUMNS OR PIERS
Comments: 
x   1.4 CEILINGS (structural)
Comments: 
x   1.5 ROOF STRUCTURE AND ATTIC
Comments: 
I=Inspected, NI=Not Inspected, NP=Not Present, R=Not Functioning or in Need of Repair
Styles & Materials
FOUNDATION:
POURED CONCRETE
 
METHOD USED TO INSPECT UNDER-FLOOR CRAWLSPACE:
NO CRAWLSPACE
 
FLOOR STRUCTURE:
SLAB
 
WALL STRUCTURE:
WOOD
 
CEILING STRUCTURE:
2X4
 
ROOF STRUCTURE:
ENGINERED WOOD TRUSS
2X4 RAFTERS
OSB
 
ROOF-TYPE:
GABLE
FLAT
 
METHOD USED TO INSPECT ATTIC:
FROM ENTRY
 

EXTERIOR

According to ASHI Standards and Practices: The inspector shall inspect: the exterior wall covering, flashing and trim. All exterior doors, attached decks, balconies, stoops, steps, porches, and their associated railings. The eaves, soffits and fascias where accessible from the ground level. The vegetation, grading, surface drainage and retaining walls on the property when any of these are likely to adversely affect the building. Walkways, patios and driveways leading to dwelling entrances. The Inspector is NOT required to inspect screening, shutters, awnings and similar seasonal accessories or fences, geological, geotechnical or hydrological conditions, recreational facilities, outbuildings, seawalls, break-walls, Docks, erosion control and earth stabilization measures.

I=Inspected, NI=Not Inspected, NP=Not Present, R=Not Functioning or in Need of Repair
I NI NP R  Inspection Items
x   2.0 WALL CLADDING FLASHING AND TRIM
Comments: 
x  x2.1 DOORS (Exterior)
Comments:
Picture 1


Picture 2

Entry door to garage from living space needs to be self closing and latching. Main entry door at Living room damaged at top of door jamb. Sliding glass doors at Living room difficult to open.
x  x2.2 WINDOWS
Comments:
Picture 1


Picture 2

One broken window at front of home and one at rear of home.
  x 2.3 GARAGE DOOR OPERATORS (Report whether or not doors will reverse when met with resistance)
Comments: 
  x 2.4 DECKS, BALCONIES, STOOPS, STEPS, AREAWAYS, PORCHES AND APPLICABLE RAILINGS
Comments: 
x   2.5 VEGETATION, GRADING, DRAINAGE, DRIVEWAYS, PATIOS, WALKWAYS AND RETAINING WALLS (With respect to their effect on the condition of the building)
Comments: 
x   2.6 EAVES, SOFFITS AND FASCIAS
Comments: 
I=Inspected, NI=Not Inspected, NP=Not Present, R=Not Functioning or in Need of Repair
Styles & Materials
SIDING STYLE:
CEMENT STUCCO
 
SIDING MATERIAL:
WOOD
CEMENT-FIBER
 
EXTERIOR ENTRY DOORS:
WOOD
STEEL
INSULATED GLASS
 
WINDOW TYPES:
SLIDERS
 
APPURTENANCE:
 
OPENER MANUFACTURER:
N/A
 
GARAGE DOOR MATERIAL:
METAL
 
TYPE:
ONE MANUAL
 
DRIVEWAY:
CONCRETE
 

ROOF SYSTEM

According to ASHI Standards and Practices: The inspector shall inspect: The roof covering, the roof drainage systems, the flashings, the skylights, chimneys and roof penetrations. Describe the roof covering and report the methods used to inspect the roof. The inspector is NOT required to inspect antennae, interiors of flues or chimneys which are not readily accessible and other installed accessories.

I=Inspected, NI=Not Inspected, NP=Not Present, R=Not Functioning or in Need of Repair
I NI NP R  Inspection Items
x   3.0 ROOF COVERINGS
Comments:We suggest you obtain a roof certification from a licensed roofing contractor or add roof to home warrantee.
x   3.1 FLASHINGS
Comments: 
x   3.2 SKYLIGHTS, CHIMNEYS AND ROOF PENETRATIONS
Comments: 
x  x3.3 ROOFING DRAINAGE SYSTEMS
Comments:
Picture 1


Picture 2

Gutter is loose at rear and front of home.
I=Inspected, NI=Not Inspected, NP=Not Present, R=Not Functioning or in Need of Repair
Styles & Materials
VIEWED ROOF COVERING FROM:
LADDER
 
CHIMNEY (exterior):
WOOD
 
STYLE:
3-TAB ASPHALT SHINGLE
GRAVEL
 

PLUMBING SYSTEM

According to ASHI Standards and Practices: The inspector shall inspect: The interior water supply and distribution systems including all fixtures and faucets, the drain, waste and vent systems including all fixtures, the water heating equipment, the vent systems, flues and chimneys, the fuel storage and fuel distribution systems, the drainage sumps, sump pumps, and related piping. Describe the water supply, drain, waste and vent piping materials, the water heating equipment including the energy source, the location of main water and main fuel shut-off valves. The inspector is NOT required to inspect the clothes washing machine connections, the interiors of flues or chimneys which are not readily accessible, wells, well pumps, or water storage related equipment, water conditioning systems, solar water heating systems, fire and lawn sprinkler systems, private waste disposal systems. The inspector is NOT required to determine whether water supply and waste disposal systems are public or private, the quantity or quality of water supply or operate safet valves or shut-off valves.

I=Inspected, NI=Not Inspected, NP=Not Present, R=Not Functioning or in Need of Repair
I NI NP R  Inspection Items
x   4.0 INTERIOR DRAIN, WASTE AND VENT SYSTEMS
Comments: 
x  x4.1 INTERIOR WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES
Comments:Sink is chipped (Cosmetic) at kitchen. Toilet won't flush unless lever is held down briefly at Hall Bath. Control knob is damaged at Hall Bath tub. Stop-valve is damaged at Hall bath tub. Toilet won't flush unless lever is held down briefly at Master Bath. Control knob is damaged at Master Bath shower.
x  x4.2 HOT WATER SYSTEMS, CONTROLS, CHIMNEYS, FLUES AND VENTS
Comments:

Strap water heater properly.
x   4.3 MAIN WATER SHUT-OFF DEVICE (Describe location)
Comments:The main shut-off is the located outside at meter (For your info).
  x 4.4 FUEL STORAGE AND DISTRIBUTION SYSTEMS (Interior fuel storage, piping, venting, supports, leaks)
Comments: 
  x 4.5 SUMP PUMP
Comments: 
I=Inspected, NI=Not Inspected, NP=Not Present, R=Not Functioning or in Need of Repair
Styles & Materials
WATER SOURCE:
PUBLIC
 
WATER FILTERS:
(We do not inspect filtration systems)
 
PLUMBING SUPPLY:
NOT VISIBLE
 
DISTRIBUTION:
COPPER
 
PLUMBING WASTE:
ABS
 
WASHER DRAIN SIZE:
3 1/2"
 
WATER HEATER POWER SOURCE:
GAS (QUICK RECOVERY)
 
CAPACITY:
40 GAL (1-2 PEOPLE)
 
MANUFACTURER:
CRAFTMASTER
 

ELECTRICAL SYSTEM

According to ASHI Standards and Practices: The inspector shall inspect the Service drop, the service entrance conductors, cables and raceways, the service equipment and main disconnects, the service grounding, the interior components of the service panels and sub panels, the conductors, the overcurrent protection devices, a representative number of installed lighting fixtures, switches and receptacles, the ground fault circuit interrupters. Describe the amperage and voltage rating of the service, the location of main disconnect (s) and sub panels., the wiring methods. The inspector shall report on the presence of solid conductor aluminum branch circuit wiring and the absence of smoke detectors. The inspector is NOT required to inspect the remote control devices unless the device is the only control device, the alarm systems and components, the low voltage wiring, systems and components, the ancillary wiring systems and components not a part of the primary electrical power distribution system, measure amperage, voltage or impedance.

I=Inspected, NI=Not Inspected, NP=Not Present, R=Not Functioning or in Need of Repair
I NI NP R  Inspection Items
x   5.0 SERVICE ENTRANCE CONDUCTORS
Comments:Clear tree limbs away from overhead service wiring.
x   5.1 SERVICE AND GROUNDING EQUIPMENT, MAIN OVERCURRENT DEVICE, MAIN AND DISTRIBUTION PANELS
Comments:

x   5.2 BRANCH CIRCUIT CONDUCTORS, OVERCURRENT DEVICES AND COMPATIBILITY OF THEIR AMPERAGE AND VOLTAGE
Comments: 
x  x5.3 CONNECTED DEVICES AND FIXTURES (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls)
Comments:
Picture 1


Picture 2


Picture 3


Picture 4


Picture 5

Light fixture does not work needs repair (try bulb first) in Living room at entry. One junction box needs a coverplate overhead in garage. Recommend licensed electrician correct. Extension cord used as permanent wiring at fluorescent light fixtures overhead in garage. Recommend licensed electrician correct. One "Three-prong" outlet is not grounded. Needs correcting at Dining Room. One "Three-prong" outlet is missing coverplate at Living Room. Wall switch is missing "cover-plate" at Hall Bath. One open splice needs placing inside a box with a coverplate overhead in garage. Recommend licensed electrician correct. 220 outlet in garage needs to be attached properly.
x   5.4 POLARITY AND GROUNDING OF RECEPTACLES WITHIN 6 FEET OF INTERIOR PLUMBING FIXTURES, AND ALL RECEPTACLES IN GARAGE, CARPORT, EXTERIOR WALLS OF INSPECTED STRUCTURE
Comments: 
x   5.5 OPERATION OF GFCI (GROUND FAULT CIRCUIT INTERRUPTERS)
Comments: 
x   5.6 SMOKE DETECTORS
Comments: 
x   5.7 LOCATION OF MAIN AND DISTRIBUTION PANELS
Comments: 
I=Inspected, NI=Not Inspected, NP=Not Present, R=Not Functioning or in Need of Repair
Styles & Materials
ELECTRICAL CONDUCTORS:
ABOVE GROUND
 
PANEL CAPACITY:
100 AMP
 
PANEL TYPE:
CIRCUITS
 
BRANCH WIRE 15 and 20 AMP:
COPPER
 
WIRING METHODS:
ROMEX
 

HEATING SYSTEM

According to ASHI Standards and Practices: The inspector shall inspect the installed heating equipment, the vent systems, flues and chimneys. Describe the energy source and the heating method by its distinguishing characteristics. The inspector is NOT required to inspect the interiors of flues or chimneys which are not readily accessible, the heat exchanger, the humidifier or dehumidifier, the electronic air filter, the solar space heating system, determine heat supply adequacy or distribution balance.

I=Inspected, NI=Not Inspected, NP=Not Present, R=Not Functioning or in Need of Repair
I NI NP R  Inspection Items
x   6.0 HEATING EQUIPMENT
Comments: 
x   6.1 NORMAL OPERATING CONTROLS
Comments: 
x   6.2 AUTOMATIC SAFETY CONTROLS
Comments: 
x   6.3 CHIMNEYS, FLUES AND VENTS
Comments: 
x   6.4 HEAT DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors)
Comments: 
x   6.5 PRESENCE OF INSTALLED HEAT SOURCE IN EACH ROOM
Comments: 
I=Inspected, NI=Not Inspected, NP=Not Present, R=Not Functioning or in Need of Repair
Styles & Materials
HEAT TYPE:
FORCED AIR
 
ENERGY SOURCE:
GAS
 
NUMBER OF HEAT SYSTEMS (excluding wood):
ONE
 
DUCTWORK:
INSULATED
 

AIR CONDITIONING SYSTEMS

According to ASHI Standards and Practices: The inspector shall inspect the installed central and through-wall cooling equipment. Describe the energy source and the cooling method by its distinguishing characteristics. The inspector is NOT required to inspect electronic air filters or determine cooling supply adequacy or distribution balance.

I=Inspected, NI=Not Inspected, NP=Not Present, R=Not Functioning or in Need of Repair
I NI NP R  Inspection Items
x   7.0 COOLING AND AIR HANDLER EQUIPMENT
Comments: 
x   7.1 NORMAL OPERATING CONTROLS
Comments: 
x   7.2 DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors)
Comments: 
x   7.3 PRESENCE OF INSTALLED COOLING SOURCE IN EACH ROOM
Comments: 
I=Inspected, NI=Not Inspected, NP=Not Present, R=Not Functioning or in Need of Repair
Styles & Materials
COOLING EQUIPMENT TYPE:
AIR CONDITIONER UNIT
 
COOLING EQUIPMENT ENERGY SOURCE:
ELECTRICITY
 
CENTRAL AIR MANUFACTURER:
UNKNOWN
 
NUMBER OF A/C UNITS:
ONE
 

INTERIOR

According to ASHI Standards and Practices: The inspector shall inspect the walls, ceilings, and floors, the steps, stairways, and railings, the countertops and a representative number of installed cabinets a representative number of doors and windows, garage doors and garage door operators. The inspector is NOT required to inspect the paint, wallpaper and other finish treatments, the carpeting, the window treatments, the central vacuum systems, the household appliances and recreational facilities.

I=Inspected, NI=Not Inspected, NP=Not Present, R=Not Functioning or in Need of Repair
I NI NP R  Inspection Items
x  x8.0 CEILINGS
Comments:Sheetrock on ceiling reveals a light stain which appears from a water leak. Stain appears old at Master Bedroom.
x   8.1 WALLS
Comments: 
x  x8.2 FLOORS
Comments:

Baseboard is missing at hall bath.
  x 8.3 STEPS, STAIRWAYS, BALCONIES AND RAILINGS
Comments: 
x  x8.4 COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS
Comments:
Picture 1


Picture 2


Picture 3


Picture 4

Tile Countertop is damaged Island and (left of stove) and (left of sink).
x  x8.5 DOORS (REPRESENTATIVE NUMBER)
Comments:Closet door need adjustment (door guides) at Master Bedroom and blue bedroom. Closet door missing at red Bedroom.
x   8.6 WINDOWS (REPRESENTATIVE NUMBER)
Comments: 
I=Inspected, NI=Not Inspected, NP=Not Present, R=Not Functioning or in Need of Repair
Styles & Materials
CEILING MATERIALS:
SHEETROCK
 
WALL MATERIAL:
SHEETROCK
 
FLOOR COVERING(S):
CARPET
TILE
WOOD
 
INTERIOR DOORS:
WOOD
 
CABINETRY:
WOOD
 
COUNTERTOP:
TILE
CULTURED MARBLE
 

INSULATION AND VENTILATION

According to ASHI Standards and Practices: The home inspector shall inspect the insulation and vapor retarders in unfinished spaces, the ventilation of attics and foundation areas, the mechanical ventilation systems. Describe the insulation and vapor retarders in unfinished spaces, the absence of insulation in unfinished spaces at conditioned surfaces. The inspector is NOT required to disturb insulation or vapor retarders and, or determine indoor air quality.

I=Inspected, NI=Not Inspected, NP=Not Present, R=Not Functioning or in Need of Repair
I NI NP R  Inspection Items
x   9.0 INSULATION AND VAPOR RETARDERS (in unfinished spaces)
Comments: 
x   9.1 VENTILATION OF ATTIC AND FOUNDATION AREAS
Comments: 
x   9.2 VENTING SYSTEMS (Kitchens, baths and laundry)
Comments: 
  x 9.3 VENTILATION FANS AND THERMOSTATIC CONTROLS (ATTIC)
Comments: 
I=Inspected, NI=Not Inspected, NP=Not Present, R=Not Functioning or in Need of Repair
Styles & Materials
ATTIC INSULATION:
BATT
 
R- VALUE:
R-19 OR BETTER
 
EXHAUST FAN TYPES:
NONE
 
DRYER POWER SOURCE:
22O ELECTRIC
 
DRYER VENT:
METAL
 

FIREPLACES AND SOLID FUEL BURNING APPLIANCES

According to ASHI Standards and Practices: The home inspector shall inspect the systems components, the vent systems, flues and chimneys. Describe the fireplaces and solid fuel burning appliances and the chimneys. The inspector is NOT required to inspect the interiors of flues or chimneys, the firescreens or doors, the seals and gaskets, the automatic fuel feed devices, the mantels and fireplace surrounds, the combustion make-up air devices, the heat distribution assists whether gravity controlled or fan assisted, ignite or extinguish fires, determine draft characteristics and or move fireplace inserts or stoves or firebox contents.

I=Inspected, NI=Not Inspected, NP=Not Present, R=Not Functioning or in Need of Repair
I NI NP R  Inspection Items
  x 10.0 SOLID FUEL HEATING DEVICES
Comments: 
 x  10.1 CHIMNEYS, FLUES AND VENTS
Comments: 
 x  10.2 GAS/LP FIRELOGS AND FIREPLACES
Comments:
Picture 1


Picture 2

Wood stove under construction.
I=Inspected, NI=Not Inspected, NP=Not Present, R=Not Functioning or in Need of Repair
Styles & Materials
TYPES OF FIREPLACES:
STAND-ALONE
 
OPERABLE FIREPLACES:
ONE
 
NUMBER OF WOODSTOVES:
ONE
 

BUILT-IN KITCHEN APPLIANCES

Exceeding the ASHI standards, the home inspector shall observe and operate the basic functions of the following kitchen appliances: Permanently installed dishwasher, through its normal cycle; Range, cook top, and permanently installed oven; Trash compactor; Garbage disposal; Ventilation equipment or range hood; and Permanently installed microwave oven. The home inspector is not required to observe: Clocks, timers, self-cleaning oven function, or thermostats for calibration or automatic operation; Non built-in appliances; or Refrigeration units. The home inspector is not required to operate: Appliances in use; or Any appliance that is shut down or otherwise inoperable.

I=Inspected, NI=Not Inspected, NP=Not Present, R=Not Functioning or in Need of Repair
I NI NP R  Inspection Items
x   11.0 DISHWASHER
Comments: 
x  x11.1 RANGES/OVENS/COOKTOPS
Comments:Knob damaged rear left.
x   11.2 RANGE HOOD
Comments: 
  x 11.3 TRASH COMPACTOR
Comments: 
x   11.4 FOOD WASTE DISPOSER
Comments: 
  x 11.5 MICROWAVE COOKING EQUIPMENT
Comments: 
I=Inspected, NI=Not Inspected, NP=Not Present, R=Not Functioning or in Need of Repair
Styles & Materials
DISHWASHER:
WHIRLPOOL
 
DISPOSER:
IN SINK ERATOR
 
EXHAUST/RANGE HOOD:
NUTONE
 
RANGE/OVEN:
TAPPAN
 

COMPLIMENTARY PHOTO VIEWS

I=Inspected, NI=Not Inspected, NP=Not Present, R=Not Functioning or in Need of Repair
I NI NP R  Inspection Items
x   12.0 KITCHEN VIEW
Comments:

x   12.1 LIVING ROOM VIEW
Comments:

x   12.2 MASTER BATH VIEW
Comments:

x   12.3 HALL BATH VIEW
Comments:

I=Inspected, NI=Not Inspected, NP=Not Present, R=Not Functioning or in Need of Repair
 

Prepared Using HomeGauge http://www.homegauge.com SHGI (c) 2000-2003 : Licensed To Jim Stasiak

SUMMARY


JS Consulting Group, LLC.

14070 Rogers Lane
Victorville, CA 92392
760) 843-4098 f. 760) 241-7076

 


The following items or discoveries indicate that these systems or components do not function as intended or adversely affects the habitabilty of the dwelling; or appear to warrant further investigation by a specialist, or requires subsequent observation.

This summary shall not contain recommendations for routine upkeep of a system or component to keep it in proper functioning condition or recommendations to upgrade or enhance the function, efficiency, or safety of the home.

This Summary is not the entire report. The complete report may include additional information of concern to the client. It is recommended that the client read the complete report.

EXTERIOR
2.1 DOORS (Exterior)
Inspected, Not Functioning or in Need of Repair
Entry door to garage from living space needs to be self closing and latching. Main entry door at Living room damaged at top of door jamb. Sliding glass doors at Living room difficult to open.
2.2 WINDOWS
Inspected, Not Functioning or in Need of Repair
One broken window at front of home and one at rear of home.

ROOF SYSTEM
3.3 ROOFING DRAINAGE SYSTEMS
Inspected, Not Functioning or in Need of Repair
Gutter is loose at rear and front of home.

PLUMBING SYSTEM
4.1 INTERIOR WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES
Inspected, Not Functioning or in Need of Repair
Sink is chipped (Cosmetic) at kitchen. Toilet won't flush unless lever is held down briefly at Hall Bath. Control knob is damaged at Hall Bath tub. Stop-valve is damaged at Hall bath tub. Toilet won't flush unless lever is held down briefly at Master Bath. Control knob is damaged at Master Bath shower.
4.2 HOT WATER SYSTEMS, CONTROLS, CHIMNEYS, FLUES AND VENTS
Inspected, Not Functioning or in Need of Repair
Strap water heater properly.

ELECTRICAL SYSTEM
5.3 CONNECTED DEVICES AND FIXTURES (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls)
Inspected, Not Functioning or in Need of Repair
Light fixture does not work needs repair (try bulb first) in Living room at entry. One junction box needs a coverplate overhead in garage. Recommend licensed electrician correct. Extension cord used as permanent wiring at fluorescent light fixtures overhead in garage. Recommend licensed electrician correct. One "Three-prong" outlet is not grounded. Needs correcting at Dining Room. One "Three-prong" outlet is missing coverplate at Living Room. Wall switch is missing "cover-plate" at Hall Bath. One open splice needs placing inside a box with a coverplate overhead in garage. Recommend licensed electrician correct. 220 outlet in garage needs to be attached properly.

INTERIOR
8.0 CEILINGS
Inspected, Not Functioning or in Need of Repair
Sheetrock on ceiling reveals a light stain which appears from a water leak. Stain appears old at Master Bedroom.
8.2 FLOORS
Inspected, Not Functioning or in Need of Repair
Baseboard is missing at hall bath.
8.4 COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS
Inspected, Not Functioning or in Need of Repair
Tile Countertop is damaged Island and (left of stove) and (left of sink).
8.5 DOORS (REPRESENTATIVE NUMBER)
Inspected, Not Functioning or in Need of Repair
Closet door need adjustment (door guides) at Master Bedroom and blue bedroom. Closet door missing at red Bedroom.

FIREPLACES AND SOLID FUEL BURNING APPLIANCES
10.2 GAS/LP FIRELOGS AND FIREPLACES
Not Inspected
Wood stove under construction.

BUILT-IN KITCHEN APPLIANCES
11.1 RANGES/OVENS/COOKTOPS
Inspected, Not Functioning or in Need of Repair
Knob damaged rear left.

JS Consulting Group, LLC.

Home inspectors are not required to report on the following: Life expectancy of any component or system; The causes of the need for a repair; The methods, materials, and costs of corrections; The suitability of the property for any specialized use; Compliance or non-compliance with codes, ordinances, statutes, regulatory requirements or restrictions; The market value of the property or its marketability; The advisability or inadvisability of purchase of the property; Any component or system that was not observed; The presence or absence of pests such as wood damaging organisms, rodents, or insects; or Cosmetic items, underground items, or items not permanently installed. Home inspectors are not required to: Offer warranties or guarantees of any kind; Calculate the strength, adequacy, or efficiency of any system or component; Enter any area or perform any procedure that may damage the property or its components or be dangerous to the home inspector or other persons; Operate any system or component that is shut down or otherwise inoperable; Operate any system or component that does not respond to normal operating controls; Disturb insulation, move personal items, panels, furniture, equipment, plant life, soil, snow, ice, or debris that obstructs access or visibility; Determine the presence or absence of any suspected adverse environmental condition or hazardous substance, including but not limited to mold, toxins, carcinogens, noise, contaminants in the building or in soil, water, and air; Determine the effectiveness of any system installed to control or remove suspected hazardous substances; Predict future condition, including but not limited to failure of components; Since this report is provided for the specific benefit of the client(s), secondary readers of this information should hire a licensed inspector to perform an inspection to meet their specific needs and to obtain current information concerning this property.

JS Consulting Group, LLC.

Prepared Using HomeGauge http://www.homegauge.com SHGI (c) 2000-2003 : Licensed To Jim Stasiak